Ask what is in the manuals, how often the maintenance is due and what it takes to do it.
What it already has at hand
- 1 manual, 1 language
- 4 planned checks, the most frequent every 12 months since the last inspection
Planned checks
Some checks are only mandatory in certain countries: pick yours and the list follows.
- 01
Periodic functional check
Periodic check that the defibrillator and its accessories are working, with the outcome recorded. When the manual gives no interval, the plan does not exceed two years. The expiry of pads and batteries depends on the model and is taken from the manual.
every 24 months since the last inspectionDM 24/4/2013Italy only
- 01
Periodic safety check · France
Check of the AED and its accessories under the country reference. Self-tests, visual checks and battery and pad expiry dates must still follow the manual.
every 12 months since the last inspectionCode de la santé publique, art. R5212-14France only
- 01
Periodic safety check · Germany
Check of the AED and its accessories under the country reference. Self-tests, visual checks and battery and pad expiry dates must still follow the manual.
every 24 months since the last inspection§ 12 MPBetreibV / DIN EN 62353Germany only
In Switzerland this product has no planned checks: the ones listed apply to other countries.
- 01
Periodic safety check · Austria
Check of the AED and its accessories under the country reference. Self-tests, visual checks and battery and pad expiry dates must still follow the manual.
every 24 months since the last inspection§ 6 MPBV / Anlage 1 MPBVAustria only
In United Kingdom this product has no planned checks: the ones listed apply to other countries.
In Spain this product has no planned checks: the ones listed apply to other countries.
In Portugal this product has no planned checks: the ones listed apply to other countries.
In United States this product has no planned checks: the ones listed apply to other countries.
In Other country this product has no planned checks: the ones listed apply to other countries.